RepairPump for Drywall Feed Pump System- For water-based materials only - - Not for use in explosive atmospheres -- Not for use with quick-set materia
Pump 24E957 Service Reference 10 3A0912APump 24E957 Service ReferencePump 24E957 Parts ListTechnical Data (Pump)306304311319309a317315b315r312315a315m
Notes3A0912A 11Notes
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th
Warning 2 3A0912AWarningThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point sym
Warning3A0912A 3MOVING PARTS HAZARDMoving parts can pinch, cut or amputate fingers and other body parts.• Keep clear of moving parts.• Do not operate
Pressure Relief Procedure 4 3A0912APressure Relief Procedure1. Turn flow control knob to fully counterclockwise.2. Place deflector in hopper or suitab
Pump Removal3A0912A 5Power Module Installation1. Remove hopper plug (117) if installed.2. Replace power (153) module and insert pump outlet into hoppe
Pump Removal 6 3A0912APump Installation1. Extend pump piston rod 1.5 in. 2. Install pump pin (7b). Verify retaining spring is in groove of connecting
Pump Service3A0912A 7Pump ServiceDisassemble the Pump1. Perform Pressure Relief Procedure, page 4.2. Perform Power Module Removal, page 4.3. Perform P
Pump Service 8 3A0912A10. Remove packings and glands from piston rod. Discard packings and glands. Remove piston wiper and back-up washer from piston
Pump Service3A0912A 96. Grease piston packings and sleeve top edge.7. Carefully slide piston assembly into top of sleeve.8. Grease top inch or two of